John Deere PL2 fault codes / John Deere PL2 diagnostic trouble codes
NOTE:This page only indicates the meaning of the fault codes. For complete troubleshooting information, see the technical manuals.
PL2 002166.09 (PL2 2166.09)— Incorrect CAN Bus Message, Information from PL1 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL1 control software. Reception of messages sent on the CAN bus by the PL1 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 002166.09 (PL2 2166.09)— Incorrect CAN Bus Message, Information from PL1 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL1 control software. Reception of messages sent on the CAN bus by the PL1 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 002168.09 (PL2 2168.09)— Incorrect CAN Bus Message, Information from PL3 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL3 control software. Reception of messages sent on the CAN bus by the PL3 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 002169.09 (PL2 2169.09)— Incorrect CAN Bus Message, Information from PL4 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL4 control software. Reception of messages sent on the CAN bus by the PL4 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 002190.09 (PL2 2190.09)— Incorrect CAN Bus Message, Information from PL1 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL1 control software. Reception of messages sent on the CAN bus by the PL1 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 002192.09 (PL2 2192.09)— Incorrect CAN Bus Message, Information from PL3 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL3 control software. Reception of messages sent on the CAN bus by the PL4 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 002193.09 (PL2 2193.09)— Incorrect CAN Bus Message, Information from PL4 Control Software
The diagnostic trouble code is generated if a data transfer problem occurs between the PL2 control software and the PL4 control software. Reception of messages sent on the CAN bus by the PL4 control software is intermittent or non-existent. This indicates an open circuit in the CAN bus, a short circuit or faulty CAN bus terminators.
PL2 516397.05 — Park Lock Solenoid 1 (DirectDrive Transmission), Current Too Low
This diagnostic trouble code is generated if the control software detects that the current value at the solenoid is too low. This may indicate an open circuit.