The VTI control software is located in the processor and controls the CommandCenter™ (display). The Processor is located behind operator’s seat and the display is located on the right side of the driver.
NOTE: The CommandCenter™ (VTI) will not sign on to the CAN Bus if a GreenStar™ Display is connected to the CAN Bus. The GreenStar™ Display must be disconnected from the CAN Bus to be able to access addresses and diagnostic trouble codes related to the CommandCenter™.
The CommandCenter™ is used to display various tractor functions and it allows the user to change the settings for these functions. In addition, it can display the area and the distance covered. It is also equipped with a USB port and a port for two cameras.
John Deere VTV fault codes / John Deere VTV diagnostic trouble codes
NOTE:This page only indicates the meaning of the fault codes. For complete troubleshooting information, see the technical manuals.
VTV 000158.03 (VTV 158.03)— Control Software, Supply Voltage (ELX) Too High
Supply voltage (ELX) above 16 V.
Reaction of the control software: Limited or no function of the control software.
VTV 000158.04 (VTV 158.04)— Control Software, Supply Voltage (ELX) Too Low
Supply voltage (ELX) below 9 V.
Reaction of the control software: Limited or no function of the control software.
VTV 000158.05 (VTV 158.05)— Control Software, Supply Voltage (ELX) Too Low During Software Installation
Supply voltage (ELX) below 9 V.
Reaction of the control software: Limited function of the control software.
VTV 000168.03 (VTV 168.03)— Control Software, Supply Voltage (BAT) Too High
Supply voltage (BAT) above 16 V.
Reaction of the control software: Limited or no function of the control software.
VTV 000441.00 (VTV 441.00)— Control Software, Display Temperature Too High
Temperature of display above 90°C (194°F). Allow display to cool.
For diagnostic procedure, see: VTV 000441.00 – Display Temperature Too High in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 000441.01 (VTV 441.01)— Control Software, Display Temperature Too Low
Temperature of display below -30°C (-22°F). Increase the display temperature (temperature inside the cab).
For diagnostic procedure, see: VTV 000441.01 – Display Temperature Too Low in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 000442.00 — Control Software, Display Temperature Too High
Temperature of display above 90°C (194°F). Allow display to cool.
For diagnostic procedure, see: VTV 000442.00 – Display Temperature Too High in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 000442.01 (VTV 442.01)— Control Software, Display Temperature Too Low
Temperature of display below -30°C (-22°F). Increase the display temperature (temperature inside the cab).
For diagnostic procedure, see: VTV 000442.01 – Display Temperature Too Low in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 001386.00 (VTV 1386.00)— Control Software, Display Temperature Too High
Temperature of display above 80°C (176°F). Allow display to cool.
For diagnostic procedure, see: VTV 001386.00 – Display Temperature Too High in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 001386.01 (VTV 1386.01)— Control Software, Display Temperature Too Low
Temperature of display below -30°C (-22°F). Increase the display temperature (temperature inside the cab).
For diagnostic procedure, see: VTV 0001386.01 – Display Temperature Too Low in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 002040.09 (VTV 2040.09)— Incorrect CAN Bus Message, Information from PDU Control Software
Data transfer problem between the VTV control software and PDU control software This indicates a problem in the CAN bus or in the transmitting control software.
Reaction of the control software: Limited or no function of the control software.
VTV 003597.02 (VTV 3597.02)— Internal 5 Volt Supply Voltage, Voltage Too High
Voltage supply of 5 V components is above 5.25 V. This indicates a short to 12 V.
For diagnostic procedure, see: VTV 003597.02 – Regulated 5.0 Volt Voltage Abnormal in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 003598.02 (VTV 3598.02)— Internal 1,5-Volt Supply Voltage, Voltage Too High
Voltage supply of 1,5-volt components too high. This indicates a short to 12 V.
For diagnostic procedure, see: VTV 003598.02 – Regulated 1.5 Volt Voltage Abnormal in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 003599.02 (VTV 3599.02)— Internal 3,3-Volt Supply Voltage, Voltage Too High
Voltage supply of 3,3-volt components too high. This indicates a short to 12 V.
For diagnostic procedure, see: VTV 003598.02 – Regulated 3.3 Volt Voltage Abnormal in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 516849.09 — Control Software, Connection to Processor Faulty
The data of the sensor screen are not transmitted correctly.
Reaction of the control software: Limited or no function of the control software.
VTV 517479.00 — Control Software, Internal Error
Error in the processor
Reaction of the control software: Limited or no function of the control software.
VTV 521780.12 — Control Software, Internal Error
Current in USB circuit too high.
For diagnostic procedure, see: VTV 521780.12 – USB Network in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 520211.05 — USB Memory Device Removed During Software Installation
USB memory device was removed during a software installation.
For diagnostic procedure, see: VTV 520211.05 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited function of the control software.
VTV 522976.02 — Control Software, Internal Error
Error when reading the internal module (EEPROM).
For diagnostic procedure, see: VTV 522976.02 – Non-Volatile Memory Read/Write Error in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 522976.11 — Control Software, Internal Error
Fault during software installation.
For diagnostic procedure, see: VTV 522976.11 – Fault During Software Installation in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 522976.12 — Control Software, Internal Error
Control software connected to wrong wiring harness or programmed incorrectly.
For diagnostic procedure, see: VTV 522976.12 – Control software connected to wrong wiring harness or programmed incorrectly. in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 522976.14 — Control Software, Internal Error
Fault during software installation.
For diagnostic procedure, see: VTV 522976.14 – Fault During Software Installation in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 522976.19 — Control Software, Internal Error
Fault during software download.
For diagnostic procedure, see: VTV 522976.19 – Fault During Software Download in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523310.12 — Control Software, Internal Error
A fault occurred when the software was launched.
For diagnostic procedure, see: VTV 523310.12 – Non-Volatile Memory Read/Write Error in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523436.00 — Control Software, Internal Error
A fault occurred when the software was launched (watchdog).
For diagnostic procedure, see: VTV 523436.00 – Fault During Software Launch (Watchdog) in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523436.08 — Control Software, Internal Error
A fault occurred when the software was launched (watchdog).
For diagnostic procedure, see: VTV 523436.08 – Fault During Software Launch (Watchdog) in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523436.09 — Control Software, Internal Error
A fault occurred when the software was launched (watchdog).
For diagnostic procedure, see: VTV 523436.09 – Fault During Software Launch (Watchdog) in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523436.12 — Control Software, Internal Error
A fault occurred when the software was launched (watchdog).
For diagnostic procedure, see: VTV 523436.12 – Fault During Software Launch (Watchdog) in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523436.14 — Control Software, Internal Error
A fault occurred when the software was launched (watchdog).
For diagnostic procedure, see: VTV 523436.14 – Fault During Software Launch (Watchdog) in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 523773.03 — Vehicle CAN BUS (500 kBd), Voltage Too High (CAN+)
CAN voltage above 4 volts.
Reaction of the control software: Limited or no function of the control software.
VTV 523773.04 — Vehicle CAN BUS (500 kBd), Voltage Too Low (CAN+)
CAN voltage below 2 volts.
Reaction of the control software: Limited or no function of the control software.
VTV 523774.03 — Vehicle CAN BUS (500 kBd), Voltage Too High (CAN-)
CAN voltage above 3 volts.
Reaction of the control software: Limited or no function of the control software.
VTV 523774.04 — Vehicle CAN BUS (500 kBd), Voltage Too Low (CAN-)
CAN voltage below 1 volt.
Reaction of the control software: Limited or no function of the control software.
VTV 524050.12 — Control Software, Internal Error
A fault occurred when the software was launched (real-time clock).
For diagnostic procedure, see: VTV 524050.12 – Real-Time Clock Fault in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524055.00 — Control Software, Internal Error
No internal memory space available.
For diagnostic procedure, see: VTV 524055.00 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524055.02 — Control Software, Internal Error
Internal memory damaged.
For diagnostic procedure, see: VTV 524055.02 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524055.12 — Control Software, Internal Error
Control software configuration incorrect.
For diagnostic procedure, see: VTV 524055.12 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524055.15 — Control Software, Internal Error
Less than 10% of internal memory free.
For diagnostic procedure, see: VTV 524055.15 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524055.16 — Control Software, Internal Error
Less than 5% of internal memory free.
For diagnostic procedure, see: VTV 524055.16 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524055.20 — Control Software, Internal Error
Less than 20% of internal memory free.
For diagnostic procedure, see: VTV 524055.20 in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524215.03 —Implement CAN Bus, Voltage Too High (CAN+)
CAN voltage above 4 volts.
Reaction of the control software: Limited or no function of the control software.
VTV 524215.04 — Implement CAN Bus, Voltage Too Low (CAN+)
CAN voltage below 2 volts.
Reaction of the control software: Limited or no function of the control software.
VTV 524217.03 — Implement CAN Bus, Voltage Too High (CAN-)
CAN voltage above 3 volts.
Reaction of the control software: Limited or no function of the control software.
VTV 524217.04 — Implement CAN Bus, Voltage Too Low (CAN-)
CAN voltage below 1 volt.
Reaction of the control software: Limited or no function of the control software.
VTV 524259.00 — Control Software, Display Temperature Too High
Temperature of display above 90°C (194°F). Allow display to cool.
For diagnostic procedure, see: VTV 524259.00 – Display Temperature Too High in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.
VTV 524259.01 — Control Software, Display Temperature Too Low
Temperature of display below -30°C (-22°F). Increase the display temperature (temperature inside the cab).
For diagnostic procedure, see: VTV 524259.01 – Display Temperature Too Low in the corresponding TM for the control unit for GreenStar™ displays.
Reaction of the control software: Limited or no function of the control software.